Sequence Reset <4>

The Sequence Reset <4> message is used by the sending application to reset the incoming sequence number on the opposing side.

TagField NameData TypeReq’dComments
Standard headerYMsgType 35=4
123GapFillFlagbooleanNIndicates replacing administrative or application messages which will not be resent. Valid values:

Y = Gap Fill mode
N = Sequence Reset mode
36NewSeqNointYNew sequence number.
Standard trailerY